Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 67
Filter
1.
Dental press j. orthod. (Impr.) ; 17(3): 88-97, May-June 2012. ilus, tab
Article in English | LILACS | ID: lil-646354

ABSTRACT

INTRODUCTION: The study of the Divine Proportion (Φ = 1.618) began with the Greeks, having as main researchers the mathematician Pythagoras and the sculptor Phidias. In Dentistry, Ricketts (1981-82) was an early to study this issue. OBJECTIVE: This study proposed to evaluate how some cephalometric measures are presented in relation to the Divine Proportion, with the total of 52 proportions, formed by 28 cephalometric landmarks. METHODS: Lateral cephalograms of 40 Class II adults patients aging from 17 to 45 years (13 male and 27 female) were evaluated. The linear distances between the landmarks were measured using Radiocef Studio software. RESULTS: After statistical analysis, the data shown an average of 65,48% in the Divine Proportion, 17,5% in the relation Ans-Op/V1S-DM16 and 97,5% in the relations Na-Me/Na-PoNa e Na-PoNa/Na-Gn. CONCLUSION: Among all cephalometric measurements investigated, the lower facial third and the dental arches showed the smallest percentages of Divine Proportion.

2.
Braz. dent. sci ; 14(1/2): 13-21, 2011. ilus, tab, graf
Article in Portuguese | LILACS, BBO | ID: lil-642707

ABSTRACT

Buscando a melhora e a individualização da análise cefalométrica na avaliação de indivíduos submetidos a tratamento ortodôntico, propôs-se, neste trabalho, avaliar a proporção divina em quatro razões cefalométricas e duas fotométricas. A amostra foi composta por 42 indivíduos adultos, na faixa etária de 18 a 45 anos, sendo 21 de cada gênero, antes e após o tratamento ortodôntico, utilizando-se radiografia cefalométrica lateral e fotografia lateral. As imagens radiográficas e as fotografias foram digitalizadas em 75 dpi com o auxílio de scanner conforme especificações da empresa que desenvolveu o software para cefalometria Radiocef Studio (Belo Horizonte, Minas Gerais, Brasil). Os pontos anatômicos foram marcados duas vezes sobre a imagem digital radiográfica e fotográfica na tela do computador. A fim de verificar o erro intraexaminador, os dados foram submetidos à análise de regressão. Após a submissão dos dados aos testes estatísticos conclui-se que as quatro razões cefalométricas, antes e após o tratamento ortodôntico, não estavam, em média, em proporção divina. Porém, houve uma aproximação, em média, da proporção divina com o tratamento em Ena-Enp/V1S-C1MS, MdOr--POOr/POOr-MxOr e Me-Ena/Ena-N. As duas razões nas fotografias, antes e após o tratamento ortodôntico, estavam em proporção divina; uma delas, B-C/A-B, aproximou-se em média ainda mais da proporção divina após o tratamento. Houve diferença estatística entre B-C/A-B e MdOr-POOr/POOr-MxOr; A-C/A-D e Me-Ena/Ena-N, estando as duas razões nas fotografias mais próximas da proporção divina antes do tratamento. Após o tratamento, somente a razão da fotografia A-C/A-D estava próxima da proporção divina.


The aim of this work is to search for better individualised analyses of the cephalometric evolution on individuals submitted to orthodontic treatment. To evaluate the divine proportion in four cephalometric and two photometric reasons. Samples of 42 individual adults, age between 18 and 45, consisting of 21 from each gender, analysed before and after the orthodontic treatment, used cephalometric and photometric lateral radiographies. The radiographic and photometric images digitalized in 75dpi and scanned according to the company, Radiocef Studio, which developed the software. The anatomic features were marked twice on digital radiographic and photographic images on a computer. In order to verify intra examination errors, the data was submitted for regression analyses. After submitting the data to the statistic testes, the conclusion was that the four cephalometric reasons, before and after the orthodontic treatment, was not, on average, in the divine proportion. However, it was closer, on average, to the divine proportion with the Ena-Enp/V1S-C1MS,MdOr/POOr-MxOr, e Me-Ena/Ena-N. The two reasons in the photographs, before and after the orthodontic treatment, were of divine proportion and one of them B-C/A-B got even closer, on average to the divine proportion after the treatment. There were statistic differences between B-C/A-B and MdOr-POOr/POOr-MxOr; A-C/A-D and Me-Ena/Ena-N, the two reasons were closer to the divine proportion in the photographs before the treatment. After the treatment, only photograph A-C/A-D was close to the divine proportion


Subject(s)
Humans , Male , Female , Young Adult , Cephalometry , Esthetics, Dental , Orthodontics , Photography
3.
Acta odontol. venez ; 48(1): 87-92, mar. 2010. ilus, tab
Article in Spanish | LILACS | ID: lil-630252

ABSTRACT

En este estudio se evaluó radiográficamente en pacientes con desorden temporomandibular la posible relación entre las alteraciones morfológicas de la apófisis estiloide del hueso temporal y el patrón de rotación mandibular. Fueron analizadas 1500 radiografías convencionales de las articulaciones temporomandibulares de los archivos del Servicio-ATM - Facultad de Odontología de la Universidad Federal de Juiz de Fora. Se observó que 83 pacientes (5,53%) presentaron al menos una de las apófisis estiloide alterada morfológicamente, siendo 9 (10,8%) del sexo masculino y 74 (89,2%) del sexo femenino. La mayoría de los pacientes de este grupo se ubica entre 41 a 50 años de edad (32,5%). Los tipos morfológicos fueron clasificados en normal (13), alargados (113), seudoarticulado (21) y segmentado (19), totalizando 166 apófisis estiloide. La clasificación de la rotación condilar encontrada fue: normal (47), hipomovilidad condilar (30) y hipermovilidad condilar (89), totalizando 166 articulaciones temporomandibulares. Por el método estadístico de Cramer`s no fueron verificados indicios de relación de que las alteraciones morfológicas de la apófisis estiloide pueden interferir en la rotación del cóndilo mandibular ni relación de simetría entre los lados derecho e izquierdo, tanto para el tipo morfológico como para la rotación condilar.


The aim of this study was to assess radiographically the possible relations between the morphological variations of the styloid process of the temporal bone and the pattern of the condylar excursions in patients with temporomandibular disorders. 1500 conventional x-rays of temporomandibular joints were analyzed, all of them from the SERVIÇO-ATM-FO/UFJF files. The results show that 83 patients (5.53%) had at least one morphologic variation of the styloid process, among which 09 (10.8%) were male and 74 (89.2%) female. Most of these patients are included in the age group of 41 to 50 years (32.5%). The morphological types were classified as normal (13), elongated (113), pseudoarticulated (21) and segmented (19), totalizing 166 styloid processes. The classification of the condylar excursion was normal (47), condylar hypomobility (30) and condylar hypermobility (89), which totals 166 temporomandibular joints. According to Cramer’s V statistic method, evidences that styloid process variations may interfere in the condylar excursion were not found; there is symmetry between the left and right sides concerning both morphological type and condylar excursion.

4.
RGO (Porto Alegre) ; 57(3): 269-272, jul.-set. 2009. ilus
Article in Portuguese | LILACS, BBO | ID: lil-527905

ABSTRACT

Objetivo: Verificar o grau de conhecimento dos cirurgiões-dentistas sobre os métodos radiográficos de localização. Métodos: Foi realizada uma pesquisa de campo com 60 cirurgiões-dentistas, sendo 25 clínicos gerais e 35 especialistas, por meio de um questionário constando 14 perguntas discursivas, nas quais puderam expressar seus conhecimentos sobre quais técnicas radiográficas de localização são conhecidas e como interpretá-las. Resultados: Verificamos que a técnica de Clark é a mais conhecida por 92% dos clínicos gerais, seguida pela técnica de Le Master, que obteve 16%. No grupo dos especialistas, Clark também aparece em primeiro lugar, com 86%, seguida pela técnica de Miller Winter, com 29%. Analisamos, por meio de uma situação clínica corriqueira, se o cirurgião-dentista sabe interpretar a técnica de Clark, tendo como resultado que entre os clínicos gerais 56% souberam interpretar a técnica, 32% erraram a resposta e 12% responderam que não sabiam. Entre os especialistas 74% acertaram a questão e 26% não responderam corretamente. Dos clínicos gerais, 72% relataram que utilizaram mais a técnica de Clark conforme aumentou o seu respectivo tempo de formado, porém, somente 56% destes demonstraram correta interpretação na situação clínica questionada. Conclusão: Sendo assim, podemos concluir que a técnica de Clark é a mais conhecida entre os cirurgiões-dentistas, porém não necessariamente sabem interpretá-la. Além disso, vimos que as outras técnicas são pouco conhecidas, nos levando a repensar sobre a grade curricular, a fim de que elas sejam mais enfatizadas, pois são igualmente importantes.


Objective: To verify dentists' about radiographic localization methods. Methods: A survey was conducted among 60 dentists, of whom 25 were general clinicians and 35 were specialists dentists, using a questionnaire with 14 discursive questions, where they could express their Knowledge about which radiographic localization techniques are known and how to interpret them. Results: It was verified that the Clark technique was most known by 92% of the general clinicians, followed by Le Master ( 16%). In the group of specialists, Clark was also ranked first by 86%, followed by the Miller Winter technique by 29%. By means of a routine clinical situation we analyzed whether the dentists knew how to interpret the Clark technique, and the results showed that among the general clinicians 56% knew how to interpret the technique, 32% gave the incorrect answer and 12% answered that they did not know. Among the specialists, 74% knew how to interpret the technique and 26% answered incorrectly. The general clinicians (72%) declared that they most frequently used the Clark technique, as the time since they graduated increased. However, only 56% of them gave the correct interpretation in the clinical situation presented in the question. Conclusion: This, it could be concluded that Clark is the best known technique among dentists (specialist or general clinicians), but they do not necessary know how to interpret it. Moreover, it was shown that the others techniques are hardly known, which leads to the conclusion that one needs to rethink the curriculum, so that they receive more emphasis, as they are equally important.


Subject(s)
Humans , Male , Female , Clinical Competence , Radiography, Dental/methods , Surveys and Questionnaires
5.
Odonto (Säo Bernardo do Campo) ; 17(33): 48-53, jan.-jun. 2009. ilus, tab, graf
Article in Portuguese | LILACS, BBO | ID: lil-542839

ABSTRACT

O objetivo nesta pesquisa foi verificar as diversas posições do forame mentoniano em relação aos pré-molares inferiores e correlacionar os lados direito (D) e esquerdo (E) conforme classificação de Tebo, Telford18 (1950), a qual possui seis classes distintas de posição que vão desde abaixo do canino inferior ao primeiro molar inferior. Foram selecionadas 104 radiografias panorâmicas de pacientes dentados totais e adultos, sendo que 67 radiografias a presença do forame foi visível em ambos os lados. Considerando o total da amostra, no lado D, a classe III apareceu em 65 casos, ou seja, 73,03%, já a classe IV apareceu 14 vezes representando 15,73% e a classe V em apenas 11,24%; as classes I, II, VI não apresentaram casos. Para o lado E, a classe III apareceu em 58 casos (69,04%), a classe V em 17 casos, ou seja, 20,24%, a classe IV obteve 8,34% ou em sete casos, as classes I e II em apenas um caso cada (1,19%) e a classe VI não houve nenhum caso. Posteriormente, comparando os dados dos lados D e E das 67 radiografias, com o teste exato de Fisher, foi possível verificar (p = 0,003) que existe uma correlação positiva entre os lados pela classificação utilizada. Os dados obtidos permitiram concluir que na grande maioria dos casos, o forame mentoniano está situado mais anteriormente ao 2º pré-molar inferior, mais precisamente entre o 1º e 2º pré-molares, ou seja, pacientes com classificação III.


The aim of this search was to verify the different position of the mental foramen in relation to the lower premolars and to correlate both sides although Tebo, Telford18 (1950) classification. This classification has six different class positions that are since above long axis of the canine to the first lower molar. 104 panoramic radiography of adult dentate patient were selected. Just in 67 radiographs, the foramen was visible in both sides. Considering the total of the sample, in right side (R), the class III appeared in 65 cases or 73,03%, already the class IV appeared in 14 times or 15,73% and the class V in only 11,24%; the class I, II, VI didn’t show some cases. To the left side (L), the class III appeared in 58 cases (69,04%), the class V in 17 cases or 20,24%, the class IV had 8,34% or in seven cases, the class I and II just in one case (1,19%) and the class VI didn’t have none. After, comparing both sides, in 67 radiographs, use the Fisher statistical test, was possible verify (p = 0,003) that exist a correlation between R and L by utilized classification. The data obtained allowed conclude that in majority of the cases the mental foramen is situated medially to second lower premolar, necessarily between first and second premolars or in classification III.


Subject(s)
Humans , Bicuspid , Mandible/anatomy & histology , Radiography, Panoramic
6.
Odonto (Säo Bernardo do Campo) ; 16(32): 47-52, jul.-dez. 2008. ilus, graf
Article in Portuguese | LILACS, BBO | ID: biblio-873696

ABSTRACT

O propósito neste trabalho foi de analisar a degradação do revelador convencional Kodak por meio da análise da densidade óptica de radiografias digitalizadas. Foram utilizados 57 filmes periapicais Ektaspeed da marca Kodak obtendo-se radiografias da região de molares inferiores de uma mandíbula seca em um aparelho de raios X Gendex 765DC. As películas foram processadas em câmara escura portátil em um número de três ao dia perfazendo um total de 27 dias de experimento. As radiografias foram escaneadas em um escaner HPScanjet 6100C e com o auxílio do software Image Tool 1,27 foi realizada a leitura média das densidades ópticas das películas obtendo-se a curva da degradação. Observamos que o início da degradação se dá com a densidade óptica ≥ 80, após 21 dias do início do experimento.


The aim in this study was to analyse the degradation of Kodak conventional developer by analysis of optical density in digitalised radiographs. Fifty seven Kodak Estaspeed periapicals films were used achieving radiographs of molars region of a dry mandible, in a Gendex 765DC machine. The films were processed in a red box three times a day during a period of 27 days. The radiographs were digitalized in a HPSanjet 6100C scanner. Using the Image Tool 1,27 software the mean of optical densities and a degradation curve were acquired. We observed the begining of degradation after 21 days from the first radiograph, when the optical density was ≥ 80.


Subject(s)
Dentistry , Quality Control , Radiographic Image Enhancement , X-Ray Film
7.
Ortodontia ; 41(3): 185-192, jul.-set. 2008. ilus
Article in Portuguese | LILACS, BBO | ID: lil-542797

ABSTRACT

O objetivo deste trabalho é apresentar um software para análise simplificada do surto de crescimento puberal (SCP) por meio ' I de radiografias dentárias. Este software foi baseado nos resultados de um estudo que avaliou o SCP, relacionando-o com a I cronologia da mineralização dentária, idade cronológica, idade dentária e idade óssea. Foi desenvolvido na Disciplina de Radiologia da Faculdade de Odontologia de São José dos Campos - Unesp e se encontra disponível no site http://www.fosjc.unesp.br/radiologia/index.htm. A ferramenta usada para o desenvolvimento desse software foi o Delphi, Object Pascal (Pascal com extensões orientadas a objetos). Concluiu-se que o emprego desse software pode ser útil ao diagnóstico e ao planejamento do tratamento ortodôntico, pois permite a avaliação do SCP de forma rápida e eficiente, por meio de radiografias dentárias periapicais ou panorâmicas.


The aim of this research is to present computer software for simplified analysis of the pubertal growth spurt with oral radiographs. This software was programmed according to the research that evaluated SCR which studied the correlation of the pubertal growth spurt with the mineralization of permanent teeth, the chronological age, the dental age and the skeletal age. The software was created at the Discipline of Oral Radiology at the School of Dentistry, São Paulo State University - Unesp - São José dos Campos- SP and free download are available at http://www.fosjc.unesp.br/radiologia/index.htm. The software was developed in Delphi Object Pascal language (Paschal with object-guided extensions). We concluded that the software may be useful for the diagnosis and in orthodontics treatment planning, since it provides a quick and efficient assessment of the pubertal growths spurt in panoramic and periapical radiographs.


Subject(s)
Puberty , Radiography, Dental , Software , Age Determination by Skeleton
8.
Rev. Assoc. Paul. Cir. Dent ; 62(3): 218-224, maio-jun. 2008. ilus, tab, graf
Article in Portuguese | LILACS, BBO | ID: lil-539252

ABSTRACT

O objetivo deste trabalho foi avaliar a capacidade dos especialistas em Radiologia Odontológica para detectar manipulações eletrônicas em imagens radiográficas digitais, avaliar o conhecimento sobre a certificação digital e seus aspectos legais. Foram utilizadas 15 radiografias, sendo dez digitalizadas e cinco digitais diretas. Foram feitas manipulações digitais em doze imagens, para isso foi utilizado o programa gráfico Adobe Photoshop versão 7.0. Posteriormente, as imagens foram apresentadas, para 20 examinadores, todos especialistas em Radiologia Odontológica. Utilizamos um questionário para coleta de dados referente às manipulações das imagens e outro para avaliar o conhecimento dos profissionais sobre a certificação digital. Para a análise estatística foi utilizado o teste z no nível de significância de 5%. Tendo como resultado, das avaliações referentes às manipulações, percentual de erro de 70% para as imagens 4, 7, 9, 10, 11, 12, 13 e 15. Os resultados referentes à certificação digital foram estatisticamente significantes, apenas, para dois itens. Concluímos que é possível manipular imagens radiográficas digitais e digitalizadas sem que os especialistas em Radiologia Odontológica detectem as alterações e que eles têm pouco conhecimento sobre certificação digital, seus aspectos legais e sua segurança.


Objective: The purpose of this study was to investigate the ability of dental radiologists to detect electronic manipulations in digital and digitized radiographic images, as well as their knowledge of digital certification of electronic documents and its legal aspects, checking the system security. Methods: A set of 15 radiographs (10 digitized and 5 digital) were used and 12 of them were digitally manipulated using the Adobe Photoshop 7.0 image-editing software, while 3 were not manipulated. All images were examined by 20 experienced dental radiologists. Data were collected using two questionnaires: one referring to image manipulation and the other relative to the examiners' knowledge of digital certification. The results were analyzed statistically by the Z test at 5% significance level. Results: The results on image manipulation showed a low percentage of right guesses. lmages 4, 7, 9, 10, 11, 12, 13 and 15 presented statistically significant results for evaluation errors, with values 70%. The results for knowledge of digital certification were statistically significant for two items only: all examiners gave a correct answer to the first item of the questionnaire, while most of them did not know the answer to the fifth item. Conclusions: ln conclusion, it was possible to manipulate electronically digital and digitized radiographic images, without the manipulations being detected by experienced dental radiologists. ln addition, the specialist observers participating in this study showed little knowledge of digital certification, mainly with respect to its legal and safety aspects. The system was proved safe, warranting the integrity of electronic files.


Subject(s)
Humans , Image Processing, Computer-Assisted , Liability, Legal , Radiography, Dental, Digital
9.
RGO (Porto Alegre) ; 56(1): 47-52, jan.-mar. 2008. ilus, graf
Article in Portuguese | LILACS | ID: lil-482685

ABSTRACT

Objetivo: Mensurar, em milímetros, a distância entre o ápice e o longo eixo do segundo pré-molar inferior ao forame mentual. Métodos: Selecionou-se 104 radiografias panorâmicas de adultos dentados. A mensuração foi realizada com a digitalização das radiografias. O programa 'Image Tool 1.28' foi utilizado para a identificação das distâncias. Os dados de 67 radiografias do total, cuja visualização do forame nos lados direito e esquerdo foi considerada boa, foram submetidas aos testes 't' Student e Sinais de Postos de Wilcoxon com a=5%. Resultados: Analisando-se a distância do longo eixo ao forame das 104 radiografias, encontrou-se localizado na medial 73,34% no direito e 69,04% no esquerdo, sendo as maiores porcentagens. Na distância entre o ápice ao forame, relacionou-se os dois lados, t(t=1,07; gl=66; p=0,288), sendo no direito (mediana; média±desvio-padrão: 4,73; 4,88±3,46) e no esquerdo (5,45; 5,23±3,68) e do longo eixo ao forame, relacionando-se os lados, paramétrico(t=1,98; gl=66; p=0,051) e não paramétrico(p=0,081), indicando no direito (mediana; média±desvio-padrão: 4,02; 3,81±4,03) e no esquerdo(3,79; 2,78±4,15). Os resultados indicaram que o forame mentual apresentou-se medialmente ao 2° pré-molar, sendo correspondente aos lados, ambos em média, direito, 4,88mm do ápice e 3,81mm a mesial, e esquerdo, 5,23mm do ápice e 2,78mm a mesial. Conclusão: Pode-se concluir que tanto a distância do ápice quanto a do longo eixo não diferiram estatisticamente para direito e esquerdo.


Objective: Measure the distance in millimeters, between the apex and the long axis of the mandibular second premolar and the mental foramen. Methods: One hundred and four panoramic radiographs of adults with teeth were selected. Measurement was performed by digitizing the radiographs. The 'Image Tool 1.28' program was used to identify the distances. The data of 67 radiographs out of the total, whose visualization of the foramen on the right and left sides was considered good, were submitted to the Student'-t test and Wilcoxon Sign Test Sinais de Postos de Wilcoxon with a=5%. Results: Analyzing the distance from the long axis to the foramen in the 104 radiographs, it was found located at the medial, 73.34% on the right and 69.04% on the left, being the highest percentages. In the distance between the apex and the foramen, the two sides wererelated, t(t=1.07; gl=66; p=0.288), on the right being (median; ean±standard deviation: 4.73; 4.88±3.46) and on the left (5.45;5.23±3.68) and from the long axis to the foramen, relating the sides, parametric (t=1.98; gl=66; p=0.051) and non-parametric (p=0.081), indicating on the right (median; mean±standard deviation: 4.02; 3.81±4.03) and on the left (3.79; .78±4.15). The results indicated that the mental foramen was presented medially to the 2nd premolar, being correspondent to the sides, both to a mean of, right, 4.88mm from the apex and 3.81 mm in the mesial direction; and left, 5.23mm from the apex and 2.78mm in the mesial direction. Conclusion: It could be concluded that both the distance from the apex and from the long axis did not differ statistically toward the right and left.


Subject(s)
Humans , Male , Female , Adult , Bicuspid , Mandible/anatomy & histology , Radiography, Panoramic
10.
Rev. odonto ciênc ; 23(1): 20-25, jan.-mar. 2008. ilus, tab, graf
Article in Portuguese | LILACS, BBO | ID: lil-487777

ABSTRACT

Objetivo: Avaliar a postura corporal de indivíduos com maloclusões esqueléticas de Classe II e III. Metodologia: Foram avaliados 59 pacientes do sexo masculino e feminino, com idade cronológica entre 7 e 12 anos. As variáveis posturais frontais (linha biocular, bicomissural e biacromial) e sagitais (lordose lombar e cervical e cabeça anteriorizada) foram analisadas em fotografias digitais de corpo inteiro em norma frontal e sagital. O tipo de maloclusão de Classe II ou III foi verificado por meio de análise cefalométrica. Resultados: Quanto à maloclusão de Classe II, 75% dos pacientes estavam fora da normalidade quanto à lordose lombar. Para lordose cervical, 25% dos pacientes com maloclusão de Classe II e Classe III apresentaram valores fora da normalidade. Noventa e dois por cento dos pacientes com maloclusão de Classe III possuíam a cabeça anteriorizada. Conclusão: Na análise frontal todos os indivíduos da amostra estavam fora do padrão de normalidade para as linhas biocular, bicomissural e biacromial. A postura anteriorizada da cabeça foi a alteração mais visualizada tanto na maloclusão de Classe II quanto na de Classe III.


Purpose: To evaluate body posture of subjects with skeletal Class II and Class III malocclusions. Methods: The sample was composed by 59 patients, aged between 7 and 12 years-old, male or female gender. Body posture variables comprised frontal (biocular, bicomissural, and biacromial lines) and saggital (lumbar and cervical lordosis, forward head position) variables, which were analyzed by means of digital photographs of the entire body. Class II or Class III malocclusions were defined by cephalometric analysis. Results: For Class II malocclusion 75% of the patients had abnormal lumbar lordosis. Regarding cervical lordosis, 25% of the patients with Class II and Class III malocclusion presented values out of the normality range. Ninety-two percent of the patients with Class III malocclusion showed forward head position. Conclusion: In the frontal analysis all subjects of this sample were out of the normal pattern for the biocular, bicomissural, and biacromial lines. The forward head posture was the most frequent alteration in subjects with Class II and Class III malocclusion.


Subject(s)
Humans , Male , Female , Child , Lordosis/complications , Malocclusion, Angle Class II/etiology , Malocclusion, Angle Class III/etiology , Posture , Stomatognathic System
11.
Rev. odonto ciênc ; 23(1): 63-66, jan.-mar. 2008. graf
Article in Portuguese | LILACS, BBO | ID: lil-487786

ABSTRACT

Objetivo: Devido ao grande uso de cimentos forradores pelo cirurgião-dentista, a finalidade deste trabalho foi medir a densidade óptica dos cimentos forradores à base de hidróxido de cálcio Biocal (Biodinâmica), Dycal (Dentsply) e Life (Kerr), e compará-la à densidade óptica dentinária. Metodologia: Corpos-de-prova foram confeccionados com espessuras de 1, 2 e 3 mm e radiografados com o aparelho Gendex 765 DC (Dentsply). Posteriormente as imagens foram capturadas pelo sistema de radiografia digital direta CCD (Visualix, Gendex/Dentsply). A densidade óptica em tons de cinza foi mensurada utilizando o programa Image Tool for Windows 1.28. Os dados foram analisados por ANOVA e teste de Tukey (nível de significânica de 5%). Resultados: O maior valor medido foi o do cimento Life com 238,66 tons de cinza na espessura de 3 mm e o menor valor foi o do Biocal com 78,66 tons de cinza para 1mm. Em dentina, obteve-se 48,67 tons de cinza para 1 mm de espessura, 64,27 para 2mm e 86,93 para 3mm. Conclusão: Todos os cimentos de hidróxido de cálcio testados apresentaram valores de densidade óptica superiores à da dentina.


Purpose: To measure the optical density of the calcium hydroxide cavity liners Biocal (Biodynamics), Dycal (Dentsply), and Life (Kerr), and to compare them with the dentin optical density. Methods: Specimens were made with 1, 2, and 3mm- thickness and x-rayed using the Gendex 765 DC (Dentsply) equipment. The images were captured by using a direct digital system (Visualix, Gendex/Dentsply). Optical density was measured in gray tones using the software Image Tool for Windows 1.28. Data were analyzed by ANOVA and Tukey's test (5% level of significance). Results: Life cement had the highest value (238.66 gray tones for 3 mm-thick) and Biocal cement showed the lowest value (78.66 gray tones for 1 mm-thick). In dentin the mean values were 48.67 grey tones for 1 mm-thick, 64.27 for 2 mm-thick, and 86.93 for 3 mm-thick. Conclusion: All tested calcium hydroxide cavity liners showed higher optical density than dentin.


Subject(s)
Humans , Dental Cements , Calcium Hydroxide , Radiography, Dental, Digital
12.
Braz. oral res ; 22(4): 346-351, 2008. ilus, graf, tab
Article in English | LILACS | ID: lil-502196

ABSTRACT

Since bovine teeth have been used as substitutes for human teeth in in vitro dental studies, the aim of this study was to compare the radiographic density of bovine teeth with that of human teeth to evaluate their usability for radiographic studies. Thirty bovine and twenty human teeth were cut transversally in 1 millimeter-thick slices. The slices were X-rayed using a digital radiographic system and an intraoral X-ray machine at 65 kVp and 7 mA. The exposure time (0.08 s) and the target-sensor distance (40 cm) were standardized for all the radiographs. The radiographic densities of the enamel, coronal dentin and radicular dentin of each slice were obtained separately using the "histogram" tool of Adobe Photoshop 7.0 software. The mean radiographic densities of the enamel, coronal dentin and radicular dentin were calculated by the arithmetic mean of the slices of each tooth. One-way ANOVA demonstrated statistically significant differences for the densities of bovine and human enamel (p < 0.05) and for bovine and human coronal dentin (p < 0.05). No statistically significant differences were found for the bovine and human radicular dentin (p > 0.05). Based on the results, the authors concluded that: a) the radiographic density of bovine enamel is significantly higher than that of human enamel; b) the radiodensity of bovine coronal dentin is statistically lower than the radiodensity of human coronal dentin; bovine radicular dentin is also less radiodense than human radicular dentin, although this difference was not statistically significant; c) bovine teeth should be used with care in radiographic in vitro studies.


Subject(s)
Animals , Cattle , Humans , Dental Enamel , Dentin , Models, Animal , Radiography, Dental, Digital , Tooth , Analysis of Variance , Dental Enamel/physiology , X-Rays
13.
Acta odontol. venez ; 45(4): 589-592, dic. 2007. ilus
Article in Spanish | LILACS | ID: lil-630038

ABSTRACT

Actualmente el sistema de tomografia computarizada Cone-beam(CBTM) puede ser empleada en el mundo médico y odontologico. Este sistema tiene como principio un algoritmo que corrige las deformidades e inestabilidades de las imágenes tomográficas computarizadas posibilitando mejor visualización y mayor exactitud en imágenes de tumores o áreas de interés profesional. Desta forma, el profesional consigue localizar fácilmente, con un minino de error, el local de interés para tratamientos quirúrgicos, radioterápicos y otros, permitiendo un mejor planeamento a sus pacientes


The cone-beam computed tomography (CBCT) has been applied to Dentistry and Medicine all over the world. This system is based on an algorithm which corrects the deformities and instabilities of the tomographic images, providing a more precise visualization of tumors and regions of interest. Therefore, the professional will easily localize, with a minimum degree of mistake, the target for surgical and radiotherapic treatments, among others, and achieve a better treatment plan for the patient


Atualmente o sistema de tomografia computadorizada Cone-beam (CBCT) vem sendo empregado em todo o mundo na Medicina e na Odontologia. Este sistema baseia-se em um algoritmo que corrige as deformidades e instabilidades das imagens tomográficas computadorizadas possibilitando assim visualizar com maior precisão as imagens de tumores ou áreas de interesse para o profissional. Desta forma o profissional consegue localizar facilmente, com mínimo de erro, o alvo de interesse para tratamentos cirúrgicos, radioterápicos, entre outros; permitindo um melhor plano de tratamento aos seus pacientes


Subject(s)
Female , Tomography, X-Ray Computed , Dentistry
14.
Ciênc. odontol. bras ; 10(4): 19-25, out.-dez. 2007. tab
Article in English | LILACS, BBO | ID: lil-500855

ABSTRACT

Many professionals currently store their restorative materials in refrigerators, even though the manufacturers do notrecommend this. This study evaluated the microleakage occurring in Class II restorations performed with compositeresin stored at different conditions and temperatures. Thirty intact human molars were employed, which received vertical slot cavity preparations with the following dimensions: 3mm in buccolingual direction, 1.5mm in mesiodistal direction, and 5mm in cervico-occlusal direction (at 1mm short of the cemento-enamel junction). Specimens were restored withthe adhesive material Prime & Bond NT and composite resin TPH Spectrum (Dentsply) with 3 different conditions: G-Iapplication of restorative materials at room temperature (nearly 25oC), G-II application of restorative materials 30 minutesafter removal from the refrigerator (25oC), and G-III application of restorative materials immediately after removalfrom the refrigerator (6oC). The specimens were sealed and immersed in 2% buffered methylene blue aqueous solutionat 37oC, for 4 hours. Thereafter, the specimens were sectioned and evaluated as to the degree of marginal leakage at thedentin-cementum/restoration interface and also as to the type of dye leakage observed. Data achieved were submitted tostatistical analysis by the non-parametric method Kruskal-Wallis (p<0.05) for comparison of the degree of leakage, andratio test for comparison of differences in the pattern of leakage. No adverse effects were observed on the occurrenceand pattern of microleakage when the restorative system was employed immediately after or 30 minutes after storagein the refrigerator, or at room temperature.


O objetivo deste estudo foi verificar a reprodutibilidade, variabilidade e fidelidade de um método de avaliação da Idade Dentária (ID) e analisar sua relação com a Idade Cronológica (IC). Foram utilizadas 53 radiografias panorâmicas, de crianças brasileiras, sendo 32 do sexo feminino e 21 do masculino, na faixa etária entre 120 a 131 meses. As avaliações foram realizadas por 4 examinadores, por meio da Tabela de Cronologia da Mineralização Dentária geral e a adaptada para os sexos. Verificou-se uma alta reprodutibilidade intra-observador e inter-observadores, tanto para o sexo feminino quanto para o masculino. Verificou-se que a ID obtida com a tabela geral é menor do que a IC para os dois sexos. Já com a tabela ajustada, observou-se que no sexo feminino as ID tendem a ser menores do que a IC, enquanto que para os indivíduos do sexo masculino, as ID tendem a ser maiores do que a IC. Entretanto, quando se subtraiu a IC da ID obtidas com a tabela ajustada, apenas 13,09% dos indivíduos do sexo masculino e 7,03% do feminino apresentavam ID fora da faixa de tolerância de ±12 meses. Quando os valores de IC foram subtraídos da ID com a tabela geral, 4,76% dos indivíduos do sexo masculino e 12,5% dos indivíduos do sexo feminino estavam acima ou abaixo do limite aceitável dos ±12 meses. Baseado nos resultados, concluímos que o método é reprodutível tanto intra quanto inter-observadores. Apesar das diferenças entre IC e ID obtidas por alguns examinadores serem estatisticamente significantes, em termos práticos, esta diferença se torna relevante somente quando ultrapassa os ±12 meses. Portanto, tanto a tabela geral quanto a ajustada são aplicáveis à população brasileira. Os Cirurgiões-dentistas não necessitam de experiência prévia com o método, por ser baseado na comparação de imagens radiográficas dos dentes com os estágios de mineralização, o qual é de fácil emprego.


Subject(s)
Humans , Male , Female , Child , Age Determination by Teeth , Radiography, Panoramic
15.
RGO (Porto Alegre) ; 55(2): 163-167, abr.-jun. 2007. ilus, tab
Article in Portuguese | LILACS, BBO | ID: lil-466450

ABSTRACT

Objetivos: Verificar a influência da marcação do ponto S, devido a imprecisão na sua reprodutibilidade, por dois métodos, sobre o traçado cefalométrico padrão USP, comparando os resultados das medidas angulares SNA, SNB e SNGn com os ângulos StNA, StNB e StNGn. Métodos: Cento e trinta e cinco radiografias cefalométricas em norma lateral, reproduzindo cada método três vezes em cada radiografia e obtendo sua média. Resultados: Os valores angulares obtidos com as medições dos dois diferentes métodos apresentaram índices de precisão próximos, sem diferença estatisticamente significantes. Os valores dos coeficientes de variação situaram-se entre 4,5% a 5,6%. Uma comparação foi efetuada entre os valores de desvio padrão por meio do teste de coeficiente de correlação linear de Pearson (r /p-valor) para a medida SNA: -0,019 /0,830; SNB: 0,010 /0,911; SNGn: 0,092 /0,286. Conclusão: Com base na análise estatística dos dados obtidos, concluímos que não houve diferença significante na reprodutibilidade das medidas angulares entre os métodos quando realizado por um único observador


Subject(s)
Humans , Cephalometry , Radiography , Reproducibility of Results
16.
Odonto (Säo Bernardo do Campo) ; 15(29): 16-24, jan.-jun. 2007. ilus, tab, graf
Article in Portuguese | LILACS, BBO | ID: lil-518380

ABSTRACT

Pitágoras, um estudioso da matemática, estabeleceu proporções descritas a partir dos padrões de beleza e harmonia estética. Sendo denominada por muitos estudiosos como proporção áurea. A proporção áurea é gerada a partir da proporcionalidade que se expressa pelo número incomensurável 1,618033... (geralmente utilizado 1,618). O estudo deste tema é de interesse das mais variadas áreas, Ortodontia, Cirurgia Bucomaxilofacial, Dentística e Cirurgia Plástica. Ricketts, 1982; Amoric, 1995; Gil, 1999; Gil & Medici Filho, 2002 ao realizarem análises cefalométricas comprovaram a existência da proporção áurea em algumas medidas. Em vista disso nosso trabalho de pesquisa verificou a proporção áurea em radiografias cefalométricas laterais em 37 pacientes portadores de má-oclusão Classe II, antes e depois do tratamento ortodôntico. Concluímos que das 19 razões estudadas, oito diferiram de forma estatística significante, sendo que sete dessas oito, aproximaram do número áureo após o tratamento.


Pythagoras, the mathematics studious, established proportions with pattern of the beauty and aesthetic harmony. Being called for many researchers as the golden proportion. The golden proportion is generated from the proportionality that if express for incommensurable number 1,618033... (generally used 1,618). The study of this theme it is the interest of the most varied areas, Orthodontics, Bucomaxilofacial Surgery, Dentistry and Plastic Surgery. Ricketts, 1982; Amoric, 1995; Gil, 1999; Gil & Medici Filho, 2002 when carrying through cephalometric analyses had proven the existence of the golden proportion in some measures. In sight of this work of research verified the golden proportion in the lateral cephalometric radiographic in 37 patients bringer Class II malocclusion, before and after the orthodontic treatment. We conclude that from the 19 studied reasons, eight had differed significant statistics, being that seven of these eight, had approached to the golden number after treatment.


Subject(s)
Humans , Child , Adolescent , Adult , Cephalometry , Face , Malocclusion, Angle Class II/therapy , Orthodontics , Radiography
17.
Rev. odonto ciênc ; 22(56): 154-159, abr.-jun. 2007. ilus, tab, graf
Article in Portuguese | LILACS, BBO | ID: lil-472485

ABSTRACT

Sabe-se que a proporção áurea pode ser aplicada nos valores estéticos, já que, algumas relações, reconhecidas como sendo belas aos olhos humanos, confortantes e prazerosas à mente humana, seguem estas proporções, além de estar associada ao crescimento e à função saudável. É propósito, neste estudo, verificar, por meio de radiografias cefalométricas laterais de indivíduos com oclusão Classe I de Angle, se algumas medidas apresentam-se áureas no esqueleto crâniofacial de indivíduos com padrões faciais distintos. Foi utilizado o programa Radiocef 2.0 (Radiomemory, Brasil) para a marcação e análise cefalométrica dos pontos nas radiografias. Os padrões faciais foram classificados pelo ângulo FMA e pelo coeficiente de Jarabak. Os dados foram submetidos aos testes t de Student, ANOVA e Tukey, e foram encontradas: 1 razão áurea no Grupo Dolico, nenhuma no Grupo Braqui e 4 razões áureas no Grupo Meso. Concluiu-se que é importante empregar análises cefalométricas individualizadas a fim de obter um plano de tratamento adequado e específico para pacientes com diferentes padrões de crescimento facial.


Subject(s)
Humans , Male , Female , Adolescent , Adult , Cephalometry , Esthetics , Face , Orthodontics
18.
Rev. Assoc. Paul. Cir. Dent ; 61(1): 29-33, jan.-fev. 2007. ilus, tab, graf
Article in Portuguese | LILACS, BBO | ID: lil-543782

ABSTRACT

Neste trabalho foi avaliada a capacidade dos cirurgiões-dentistas em detectar manipulações em imagens radiográficas digitais. Foram selecionadas cinco imagens radiográficas periapicais e apenas três imagens foram manipuladas. As manipulações foram feitas por meio do programa de edição de imagens Adobe Photoshop versão 7.0. Foram selecionados dez examinadores da faculdade de Odontologia de São José dos Campos - Unesp, que deveriam informar se as imagens foram manipuladas e indicar a região em que houve a manipulação. Os resultados foram estatisticamente significantes nas avaliações das imagens 2, 3 e 5, as quais apresentaram o valor de p<0,05. Portanto concluímos que é muito difícil, os profissionais da área, detectarem as manipulações nas imagens radiográficas.


Our aim on the present paper was to assess the ability of Dentists to detect manipulations of digital radiographic images. Five digital radiographies were selected and manipulated on the Adobe Photoshop v. 7.0 image editor. The manipulated images were submitted for evaluation of 10 examiners at the Dentistry School of São José dos Campos - UNESP. The examiners had to indicate if the images were manipulated or not, and in case of an affirmative answer, they had also to indicate the region were they found the manipulation. The results demonstrated a low percentage of right answers. Statistically significant differences were found for the answers of images 2, 3 and 5 (p<0.05). Therefore, we concluded that it is difficult for Dentists to detect manipulations of digital radiographic images.


Subject(s)
Practice Patterns, Dentists' , Radiographic Image Interpretation, Computer-Assisted
19.
Braz. oral res ; 21(3): 259-264, 2007. ilus, graf
Article in English | LILACS | ID: lil-458600

ABSTRACT

The aim of this research was to evaluate dental age in 102 patients with Down Syndrome, using panoramic radiographs. A software program developed by the Discipline of Radiology, School of Dentistry of São José dos Campos, São Paulo State University (UNESP), was used. A table of mineralization chronology of permanent teeth among Brazilians conceived by Nicodemo, Moraes and Medici Filho was used within the software. Statistical analysis of the results showed that 70.91 percent of the males and 61.21 percent of the females presented advanced dental age. Only 32.09 percent of the males and 38.79 percent of the females presented delayed dental age. Regarding the differences between the dental and chronological ages, two thirds of the males and females presented dental age with differences of up to 12 months, which means that they can be considered to be within normal standards, whereas only 18.87 percent of the males and 10.21 percent of the females presented dental age outside normal standards, with differences of over 24 months. In conclusion, the majority of the patients with Down Syndrome were considered to be within the normal standards of mineralization chronology.


O objetivo desta pesquisa foi avaliar a idade dentária em 102 indivíduos com síndrome de Down, por meio de radiografias panorâmicas. Foi usado um "software" desenvolvido pela disciplina de Radiologia da Faculdade de Odontologia de São José dos Campos (UNESP). Neste "software", foi utilizada a tabela de cronologia de mineralização dos dentes permanentes entre brasileiros, de Nicodemo, Moraes e Medici Filho. A análise estatística dos resultados mostrou que 70,91 por cento dos indivíduos do sexo masculino e 61,21 por cento do sexo feminino apresentaram idade dentária adiantada. Apenas 32,09 por cento dos indivíduos do sexo masculino e 38,79 por cento dos indivíduos do sexo feminino apresentaram idade dentária atrasada. Com relação às diferenças entre idade dentária e idade cronológica, dois terços dos indivíduos dos sexos masculino e feminino apresentaram idades dentárias com até 12 meses de diferença, o que significa que estão dentro do padrão de normalidade; enquanto 18,87 por cento dos indivíduos do sexo masculino e 10,21 por cento dos indivíduos do sexo feminino apresentaram idades dentárias fora do padrão de normalidade com diferenças acima de 24 meses. Concluiu-se que a maioria dos pacientes com síndrome de Down estava dentro do padrão de normalidade de desenvolvimento dentário.


Subject(s)
Adolescent , Child , Child, Preschool , Female , Humans , Male , Age Determination by Teeth , Dental Care for Disabled , Down Syndrome , Molar, Third/physiology , Radiography, Panoramic , Tooth Calcification , Dentition, Permanent , Sex Factors
20.
Acta odontol. venez ; 45(1): 79-82, 2007. tab
Article in Spanish | LILACS | ID: lil-483969

ABSTRACT

El objetivo de este estudio fue comparar dos aparatos digitales directos con la radiografía periapical convencional y con la medida real evaluada por un vernier digital analizando los resultados en relación al grado de fidelidad de las mediciones. Fueron utilizados veinte dientes íntegros unirradiculares permanentes en que se realizó la medida con el vernier. En seguida, se incluyo en cera utilidad 7, se hizo las radiografías utilizando las técnicas periapicales digitales y convencional. Para la incidencia radiográfica, el aparato utilizado fue el 765 DC® (Gendex® -Il- USA), con 65 kVp, 7mA, 30cm de distancia foco- película, 0.02s y 0,16s de tiempo de exposición para el digital y convencional respectivamente. Los aparatos digitales directos utilizados fueron: el RVG® (Trophy,Vallée- Francia) y el Visualix® (Gendex® -Il- USA) . La medida de los elementos dentarios fue realizada mediante la propia herramienta de medida de los aparatos digitales. Para la técnica convencional, la medida fue realizada por un vernier digital. Con los valores obtenidos, se realizó el test Tuckey y el test t pareado con corrección de Bonferroni. Los resultados indican tener diferencias estadísticamente significantes. Sin embargo, concluimos que los sistemas digitales directos y el método convencional son confiables en la utilización de las mediciones en la práctica odontológica y que el Visualix presentó los mejores resultados


The aim of this study was compared two direct digital devices with the periapical radiograph and with the real measure evaluated by a digital caliper being analyzed the results how to the degree of allegiance of the measurement. Twenty uniroot permanent teeth were utilized to realize the digital caliper measurement. After that, the teeth were included in nº7 wax utility and conventional periapical and digital radiographs were taken. The X-Ray machine used was the 765 DC® (Gendex® -Il- USA) with 65 kVp, 7mA, 30cm distance focus- film and exposure time to digital and conventional periapical of the 0.02s and 0,16s respectively. The direct digital devices used were the RVG® (Trophy,Vallée- France) and the Visualix® (Gendex® -Il- USA). The measurement of the teeth were realized using the own measure tool of the digitals devices software. To conventional technique, the digital caliper were used to realize the measurement. The values obtained were submitted to Tukey test and t paread test with the Bonferroni correction. The results showed possess statistically significant difference. However, it's possible to conclude that the direct digital devices and the conventional method are trustworthily in measurement in the dental clinical pratice, being the Visualix® showed the best results.


O objetivo deste estudo foi comparar dois sistemas digitais diretos, com a radiografia periapical convencional e com a medida real avaliada por um paquímetro digital, analisando os resultados quanto ao grau de fidelidade das mensurações. Foram utilizados vinte dentes hígidos unirradiculares permanentes o qual foi realizada a mensuração com um paquímetro digital. Posteriormente, foram incluídos em cera utilidade 7, radiografados utilizando as técnicas periapicais digitais e convencionais. Para a incidência radiográfica, o aparelho utilizado foi o 765 DC® (Gendex® -Il- USA), com 65 kVp, 7mA, 30cm de distância foco- filme, 0.02s e 0,16s de tempo de exposição para o digital e convencional respectivamente. Os aparelhos digitais diretos utilizados foram : o RVG® (Trophy,Vallée- França) e o Visualix® (Gendex® -Il- USA). A mensuração dos elementos dentários foi realizada mediante a própria ferramenta de medida dos aparelhos digitais. Para a técnica convencional, a mensuração foi realizada mediante um paquímetro digital. Para os valores obtidos, foi realizado o teste Tuckey e o teste t pareado com correção de Bonferroni.Os resultados mostraram possuir diferenças estatisticamente significantes, apesar disso, concluímos que os sistemas digitais diretos e o método convencional são confiáveis na utilização das mensurações, sendo que o VISUALIX apresentou os melhores resultados.


Subject(s)
Diagnostic Imaging/methods , Odontometry/methods , Radiography, Dental, Digital/instrumentation , Radiography, Dental, Digital/methods , Radiography, Dental/methods , Analysis of Variance , Brazil , Tooth , Data Interpretation, Statistical
SELECTION OF CITATIONS
SEARCH DETAIL